Image of INVESTIGATION OF INTERNAL PIPELINE CONDITION USING INDUSTRIAL GAMMA COMPUTED TOMOGRAPHY (CT) SYSTEM | Prosiding SKN 2019
Penanda Bagikan

Artikel

INVESTIGATION OF INTERNAL PIPELINE CONDITION USING INDUSTRIAL GAMMA COMPUTED TOMOGRAPHY (CT) SYSTEM | Prosiding SKN 2019

Azmi, Bayu - Nama Orang; Wibisono - Nama Orang; R. Ningsih, Firliyani - Nama Orang;

Pipeline is an important part in industry that functions to transport fluids. During the process, pipeline may contain deposits which can cause scale. Pipe scale is a problem that can disrupt the fluid flow rate that affects the production process and has high potential hazard. Industrial gamma computed tomography (CT) system has been designed to investigate thickness or the profile of scale inside the pipeline. By using 137Cs (2.96 GBq) as the gamma transmitter and NaI(Tl) scintillation detector as the receiver, the system is able to visualize the internal structure of an object. In this research, a pipe with artificial scale was used as an object (OD= 168 mm, ID= 154 mm, and scale thickness= 18 mm). The object was scanned in translation and rotation. The translational scan step is every 3 mm. While the rotational scan was performed every 2.810 (64 projections). The data were reconstructed to image using filtered back projection (FPB) algorithm. The reconstructed image is able to show pipe wall, pipe scale, and the void with resolution of 3 mm each pixel. Based on image’s pixels measurement, OD= 55 pixels (165 mm), ID= 50 pixels (150 mm), and scale thickness= 6 pixels (18 mm).


Ketersediaan
#
PERPUSTAKAAN BAPETEN (600) 621.483 AZM I
A0537/2026
Tersedia
Informasi Detail
Judul Seri
Regulasi dan Keselamatan Nuklir Menyongsong Industri 4.0
No. Panggil
621.483 AZM I
Penerbit
Bandung : BAPETEN & Universitas Padjajaran., 2019
Deskripsi Fisik
4p. : Illus. ; pdf
Bahasa
English
ISBN/ISSN
1412-3258
Klasifikasi
621.483
Tipe Isi
-
Tipe Media
-
Tipe Pembawa
-
Edisi
2019
Subjek
Tomography
Info Detail Spesifik
Prosiding SKN 2019
Pernyataan Tanggungjawab
-
Versi lain/terkait
JudulEdisiBahasa
Computed Tomography (CT)Image Reconstruction Using Matlab Programming-en
Kajian Computed Tomography Dose Index (CTDI) Untuk Multislice Helical CT-id
Lampiran Berkas
  • INVESTIGATION OF INTERNAL PIPELINE CONDITION USING INDUSTRIAL GAMMA COMPUTED TOMOGRAPHY (CT) SYSTEM | Prosiding SKN 2019 | Nuklir
    Baca/Unduh PDF
    Other Resource Link
Komentar

Anda harus masuk sebelum memberikan komentar

PERPUSTAKAAN BAPETEN
  • Informasi
  • Layanan
  • Pustakawan
  • Area Anggota

Tentang Kami

Perpustakaan BAPETEN adalah perpustakaan khusus LPNK yang menyediakan berbagai informasi dan referensi terkait pengawasan ketenaganukliran.

Cari

masukkan satu atau lebih kata kunci dari judul, pengarang, atau subjek

Donasi untuk SLiMS Kontribusi untuk SLiMS?

© 2026 — Senayan Developer Community

Ditenagai oleh SLiMS
Pilih subjek yang menarik bagi Anda
  • Karya Umum
  • Filsafat
  • Agama
  • Ilmu-ilmu Sosial
  • Bahasa
  • Ilmu-ilmu Murni
  • Ilmu-ilmu Terapan
  • Kesenian, Hiburan, dan Olahraga
  • Kesusastraan
  • Geografi dan Sejarah
Icons made by Freepik from www.flaticon.com
Pencarian Spesifik
Kemana ingin Anda bagikan?